単位:A
機種 | 形式 | 200V 50Hz | 200V 60Hz | 220V 60Hz | 起動電流 |
---|---|---|---|---|---|
小形 (OL含む) |
1/6S(H)2 | 2.7 | 2.6 | 2.6 | 10.5 |
1/4S(H)2 | 3.3 | 3.5 | 3.3 | 10.5 | |
1/2S(H)2 | 4.1 | 4.4 | 4.1 | 17 | |
標準形 (OL含む) |
1〜2S(H) | 5.2 | 5.3 | 5.2 | 18 |
2.8SH | 5.1 | 5.2 | 5.1 | 18 | |
5SH | 5.2 | 5.3 | 5.2 | 18 | |
高速形 | 1FH | 6.5 | 7.0 | 6.5 | 34 |
2FH | 13 | 14 | 14 | 94 | |
2.8FH | 10.5 | 11.5 | 10.5 | 94 | |
5FH | 12 | 14 | 12 | 94 | |
二重速形 | 1/4SN(H)2 | 3.3/2.0 | 3.0/1.7 | 3.3/2.0 | 14/3.5 |
1/2SN(H)2 | 5.2/4.0 | 5.0/3.0 | 5.2/3.5 | 21/6.5 | |
1〜2SN(H) | 6.5/5.3 | 6.2/4.0 | 6.2/4.5 | 22/7 | |
2FNH | 14.0/12.0 | 14.0/9.5 | 14.0/11.0 | 82/18 | |
2.8FNH | 14.0/13.0 | 13.0/9.5 | 13.0/9.5 | 82/18 | |
5FNH | 14.0/12.0 | 14.0/9.5 | 14.0/11.0 | 82/18 | |
ミニ | 1/6E(H)2 | 1.6 | 1.4 | ― | 5 |
1/4E(H)2 | 1.8 | 1.6 | ― | 5 | |
1/2〜0.9E(H)2 | 3.4 | 3.0 | ― | 11 | |
電動トロリ | 1/2ET2 | 1.2 | 1.0 | 1.0 | 4.1 |
1〜2ET2 | 1.6 | 1.4 | 1.4 | 7 | |
3〜5ET2 | 3.5 | 2.5 | 3.0 | 16.5 | |
1/2ET2(半速) | 1.0 | 0.8 | 0.8 | 2.0 | |
1〜2ET2(半速) | 2.2 | 1.5 | 1.8 | 6 | |
3〜5ET2(半速) | 3.2 | 2.1 | 2.5 | 9 | |
1ST2 | 1.6 | 1.2 | 1.3 | 4.5 | |
2ST2 | 2.7 | 1.8 | 2.2 | 9.5 | |
3ST2 | 2.5 | 1.8 | 2.2 | 16.5 | |
大形 | 10FH | 13×2 | 14×2 | 13×2 | 94×2 |
10FH-ET02(本体) | 13×2 | 14×2 | 13×2 | 94×2 | |
10FH-ET02(トロリ) | 3.2×2 | 2.1×2 | 2.5×2 | 9×2 |
単位:A
機種 | 形式 | 100V 50Hz | 100V 60Hz | 起動電流 |
---|---|---|---|---|
小形 | 1/4SS(H)2 | 8.5 | 8.0 | 29 |
1/2SS(H)2 | 9.5 | 11.0 | 32 | |
標準形 | 1SS(H) | 13 | 18 | 44 |
ミニ | 1/6・1/4E(H)1 | 3.4 | 4.0 | 7 |
1/2・0.9E(H)1 | 7.8 | 6.5 | 16 | |
電動トロリ | 1STS | 2.8 | 2.6 | 8 |