When I-Beam is used for traveling rail, set the I-Beam so that the maximum span will be less than following length. (The following length is calculated as the allowable deflection is 1/5000.)
unit : m
Rated Load Beam Size(mm) |
~500kg | 1t | 2t | 3t | 5t | 10t | 15t |
---|---|---|---|---|---|---|---|
150 × 75 × 5.5 | 3.5 | 2.4 | — | — | — | — | — |
200 × 100 × 7 | 5.6 | 3.8 | 2.6 | 2 | — | — | — |
250 × 125 × 7.5 | 8.2 | 5.9 | 4.1 | 3.4 | 2.1 | — | — |
250 × 125 × 10 | 9.1 | 7 | 4.9 | 4 | 3 | — | — |
300 × 150 × 11.5 | — | — | 7 | 5.7 | 4.4 | 3 | 2.4 |
350 × 150 × 12 | — | — | 8.2 | 7 | 5.3 | 3.5 | 2.8 |
400 × 150 × 12.5 | — | — | 9.2 | 8 | 6.1 | 4.3 | 3.5 |
450 × 150 × 11 | — | — | — | — | 7 | 5 | 4 |