Skip to main content

Hitachi

Hitachi Industrial Equipment Systems Co., Ltd.

Function Standard type
High Speed Type Time Delay Type Automatic reset type Latched Type Relay: Automatic Reset
Lamp: Latched
Type-Form R-NZB R-NZBT R-NZBK R-NZBL R-NZBR
Rated Voltage (AC, V) 100, 200, 240, 380, 415
Frequency (Hz) 50, 60
Rated Sensitivity Current (mA) 50 / 100 / 200 / 500 /1000 (1) (30) 100 / 200 / 500 /
1000 / 2000 (1)
50 /100 / 200 / 500 /1000 (1) (30) 100 / 200 / 500 /1000 / 2000 (1)
Operating Time (sec.) 0.1 or less 0.3
(0.2 / 0.5 / 2 / 4 (1))
0.1 or less
0.3
0.3
(0.2 / 0.5 / 2 / 4 (1))
Alarm Contact 1c + 1a
Dimensions (mm)Dimensions a 80
b 80
c 115
Weight (kg) 0.45

Note

*1
Interchangeable by manual operation.
*2
Rating with (  ) are manufactured by customer's order.
*3
Rated Voltage Applicable Circuit Voltage Remarks
100V 100 - 110V Interchangealbe by tap changing
200V 200 - 220V
240V 230 - 240V  
380V 380V  
415V 400•415•440•460V (60Hz)  

ZCT WITH PRIMARY CONDUCTORS

TYPE Z-400B Z-600B Z-800B Z-1000B Z-1200B Z-2000B
Number of Poles 3 4 3 4 3 4 3 4 3 4 3 4
Continuous Thermal Current (A) 400 600 800 1000 1200 2000
Rated Voltage (AC, V) 600
Frequency (Hz) 50,60
Rated withstandard Current (kA) 100 (peak value) 150 (peak value)
Rated Sensitivity Current Refer to Earth Leakage Relays
Operating time (sec.) Ditto
DimensionsDimensions A 220 315 220 315 240 320 240 320 240 320 310 380
B 348 348 348 348 380 380 380 380 380 380 300 300
B1 400 400 460 460 480 480 480 480 480 480 600 600
C 187 214 187 214 214 239 214 239 214 239 242 284
Weight (kg) 11 15 11.2 16 12.3 17 12.3 17 13 18 30 42

ZERO-PHASE-SEQUENCE CURRENT TRANSFORMER

TYPE Aperture Diameter Maximum Available Wire Size
Vinyl-insulated
600V Wire (IV)
Polyethylene-insulated
600V Wire (CV)
2-wire 3-wire 4-wire 2-wire 3-wire 4-wire
ZR-15 φ15 14 mm2
(88A)
8 mm2
(61A)
8 mm2
(61A)
2 mm2
(33A)
2 mm2
(33A)
ZR-30B φ30 60 mm2
(217A)
50 mm2
(190A)
38 mm2
(162A)
38 mm2
(190A)
22 mm2
(135A)
14 mm2
(105A)
ZR-58B φ58 250 mm2
(556A)
200 mm2
(469A)
150 mm2
(395A)
200 mm2
(560A)
150 mm2
(480A)
100 mm2
(365A)
ZR-65 φ65 325 mm2
(650A)
250 mm2
(556A)
200 mm2
(469A)
250 mm2
(655A)
200 mm2
(560A)
150 mm2
(480A)
ZR-80 φ80 500 mm2
(842A)
500 mm2
(842A)
325 mm2
(650A)
400 mm2
(870A)
325 mm2
(760A)
250 mm2
(655A)
ZR-100 φ100 500 mm2×4
(1,684A)
400 mm2×6
(1,490A)
500 mm2
(842A)
600 mm2
(1,140A)
600 mm2
(1,140A)
400 mm2
(870A)
ZR-120 φ120 325 mm2×9
(1,950A)
400 mm2×8
(1,490A)
1,000 mm2
(1,600A)
800 mm2
(1,370A)
600 mm2
(1,140A)

Product Inquiry