Skip to main content

Hitachi

Hitachi Industrial Equipment Systems Co., Ltd.

Specifications : 200V class

Specifications BRD-S3 BRD-E3 BRD-E3-30K BRD-E3-55K
Discharging
resistance
Short period *1 4Ω or more
(20%ED)
2Ω or more
(20%ED)
Continuous 17Ω 17Ω
Voltage Operating Voltage ON…362.5±5V OFF…355±5V
[−5%, −10% settable]
Built-in resistor 120W
20Ω
120W
180Ω
Built-in resistor
allowable operating cycle *2
Continuous ON period
0.5sec. max.
Allowable operating cycle
1/50
(0.5sec. ON, 25sec.OFF)
Continuous ON period
10sec. max.
Allowable operating cycle
1/10
(10sec. ON, 90sec. OFF)
6.6kW instantaneously
120W rated
0.7kW instantaneously
120W rated
Operation indicator LED ON
Protective
functions
Built-in resistor Relay is activated
at 200°C or more
Power module Relay is activated at 100°C or more
Relay Relay rating AC240V 3A(R load)0.2A(L load), DC36V 2A
Maximum number of
parallel-connected operation
5 2
General specifications Ambient temperature −10 to 50°C −10 to 50°C
Storage temperature −10 to 60°C
Humidity 20 to 90% (no condensation)
Vibration 0.6G or less 0.5G or less
Location Altitude 1,000m or less, indoors (no corrosive gases or dust)
Color Munsell 5Y7/1, cooling fins in base color of aluminum

Specifications : 400V class

Specifications BRD-EZ3 BRD-EZ3-30K BRD-EZ3-55K BRD-EZ3-110K
Discharging
resistance
Short period *1 10Ω or more
(10%ED)
6Ω or more
(20%ED)
3Ω or more
(20%ED)
Continuous 34Ω 24Ω 12Ω
Voltage Operating
Voltage
ON…725±5V OFF…710±5V
[−5%, −10% settable]
ON…737±5V OFF…720±5V
[−5%, −10% settable]
Built-in resistor 120W 180Ω
(2pcs. in series)
Built-in resistor
allowable operating cycle *2
Continuous ON period
10sec. max.
Allowable operating cycle
1/10
(10sec. ON, 90sec. OFF)
1.5kW instantaneously
240W rated
Operation indicator LED ON
Protective
functions
Built-in resistor Relay is activated
at 200°C or more
*3 *3 *3
Power module Relay is activated at 100°C or more
Relay Relay rating AC240V 3A(R load)0.2A(L load), DC36V 2A
Maximum number of
parallel-connected operation
5 2
General
specifications
Ambient temperature −10 to 50°C −10 to 50°C
Storage temperature −10 to 60°C
Humidity 20 to 90% (no condensation)
Vibration 0.6G or less 0.5G or less
Location Altitude 1,000m or less, indoors (no corrosive gases or dust)
Color Munsell 5Y7/1, cooling fins in base color of aluminum
*1
Short period means that the BRD unit operates for 1-minute in the 10-minute cycle (10%ED) and BRD- EZ2-30K unit operates for 10-seconds in the 100-seconds cycle (10%ED).
*2
When using an external resistor, the internal resistor connection has to be removed.
*3
For resistor thermal protection, add a thermal relay that matches to the resistor

Product Inquiry