TYPE F-1200K F-1200C FX1200 F-1600CB F-1600B F-1600E
Numner of Poles 3 4 3 4 3 3 4 3 4 3 4
Rated Current (A)
(Base ambient temperature 40℃)
1200 600 / 700 / 800
1000 /1200
adjustable
600 / 700 / 800
1000 /1200
adjustable
800 / 900 /1000
1200 /1400 /1600
adjustable
1000 1200 1400 1600 800 / 900 /1000
1200 /1400 /1600
adjustable
Rated Insulation Voltage Ui (V) 690 690 690 690 690 690
Rated Impulse withstand Voltage Uimp (kV) 8 8 8 8 8 8
Rated
Breaking
Capacity (kA)
IEC 60947-2
(Icu/Ics)
AC 690V 45 / 34
440V 85 / 22 85 / 22 85 / 85 85 / 22 85 / 22 85 / 64
415V 85 / 22 85 / 22 85 / 85 85 / 22 85 / 22 85 / 64
400V 85 / 22 85 / 22 85 / 85 85 / 22 85 / 22 100 / 75
380V 85 / 22 85 / 22 85 / 85 85 / 22 85 / 22 100 / 75
240V 125 / 32 125 / 32 125 / 125 125 / 32 125 / 32 125 / 94
230V 125 / 32 125 / 32 125 / 125 125 / 32 125 / 32 125 / 94
DC 250V 40 / 10 40 / 10
125V 40 / 10 40 / 10
DimensionsDimensions a 210 280 210 280 210 210 280 210 280 210 280
b 410 410 410 410 410 370
c 150 150 150 150 150 140
d 190 190 190 190 190 191
Net Weight (kg) 26 33 26 33 26 37 49 37 49 27 36
Standard Connection Type Front Bar Terminal Front Bar Terminal Front Bar Terminal Front Bar Terminal Front Bar Terminal Front Bar Terminal
Phase Separator for Line Side ● (*2) ● (*2) ● (*2) ● (*2) ● (*2)
Interior
Accessories
Alarm Switch AL ○ (*3)
Auxiliary Switch AUX ○ (*3)
Shunt Trip SHT ○ (*3)
Undervoltage Trip UVT
Terminal Block TB
TB2
Exterior
Accessories
Rear-connecting
Stud
STB
BSD
Flush Mounting Base
Assembly
GKW(STB)
GK•GKW(BSD) ○ (GK) ○ (GK) ○ (GK) ○ (GK) ○ (GK) ○ (GK)
Plug-in Mounting
Base Assembly
PK
Drawout Assembly PDK
Mechanical Interlock MIW MIW-8 MIW-8 MIW-8 MIW-8D MIW-8D
Motor-operating
Mechanism
MMK-S
MMK-C
MMK
Lock Cover LC
Handle Lock HL
Handle Operating
Mechanism
HA HA-801 HA-801 HA-801 HA-801 HA-801
HM
Terminal
Cover
Front Type TMC TMC-6 TMC-6 TMC-6B
Short Type
Long Type
Rear Type BTC
IEC Rail 35 mm
Automatic Tripping Device Thermal-Magnetic Electronic Relay Electronic Relay Electronic Relay Magnetic Electronic Relay
Trip Button

Note

1
● : Standard      ○ : Option
2
2-pole types marked with (*1) are supplied in 3-pole type.
3
Please state "For DC" in case of DC use. Especially, state please state kind of the power supply in case of from 30 to 100AF.
4
Flush Mounting Base Assembly, GKW are standard in case of up to 250AF and FX400.
5
Please state that number of poles of breakers when order MIW.
6
Installation of phase separators is required in case of types marked (*2).
7
Tripping system of F-1000K and F-1200K are induction heat system, please state frequency when ordering.
8
For DC use, the tripping character is only instantaneous trip in case of F-1000K and F-1200K.
9