Three-phases 200V class

Models NES1- 002LB 004LB 007LB 015LB 022LB
Applicable Motor Size*1 kW 0.2 0.4 0.75 1.5 2.2
HP 1/4 1/2 1 2 3
Rated capacity (kVA) 200V 0.4 0.9 1.3 2.4 3.4
240V 0.5 1 1.6 2.9 4.1
Rated input voltage (V) Three phases 200V –15% to 240V +10%, 50/60Hz ±5%
Rated output voltage (V) Three phases 200 to 240V
(corresponding to input voltage)
Rated output current (A)*2 1.4 2.6 4 7.1 10.0
Cooling Method Self cooling Force Ventilation
Braking Torque *3
(capacitor feedback )
Appx. 50% Appx. 20 to 40%
Weight (kg) 0.7 0.8 0.9 1.2 1.3

Single-phase 200V class

Models NES1- 002SB 004SB 007SB 015SB 022SB
Applicable Motor Size*1 kW 0.2 0.4 0.75 1.5 2.2
HP 1/4 1/2 1 2 3
Rated capacity (kVA) 200V 0.4 0.9 1.3 2.4 3.4
240V 0.5 1 1.6 2.9 4.1
Rated input voltage (V) Single phase 200V –15% to 240V +10%, 50/60Hz ±5%
Rated output voltage (V) Three phases 200 to 240V
(corresponding to input voltage)
Rated output current (A)*2 1.4 2.6 4 7.1 10.0
Cooling Method Self cooling Force Ventilation
Braking Torque *3
(capacitor feedback )
Appx. 50% Appx. 20 to 40%
Weight (kg) 0.7 0.8 1.0 1.2 1.3

Three-phases 400V class

Models NES1- 004HB 007HB 015HB 022HB 040HB
Applicable motor size,
4-pole*1
kW 0.4 0.75 1.5 2.2 4.0
HP 1/2 1 2 3 5
Rated capacity (kVA) 380V 0.9 1.6 2.6 3.6 6.0
480V 1.2 2.0 3.4 4.5 7.6
Rated Input Voltage(V) Three-phases 380 to 480V +10%, -15%, 50/60Hz ±5%
Rated output voltage(V) Three-phases(3-wire) 380 to 480V
(corresponding to input voltage)
Rated output current (A)*2 1.5 2.5 4.1 5.5 9.2
Cooling Method Self cooling Force Ventilation
Braking Torque *3
(capacitor feedback )
Appx. 50% Appx. 20 to 40%
Weight (kg) 0.9 1.0 1.1 1.2

General Specifications

Item Specificattion
Enclosure *4 IP20
Control Control Method PWM
Output Frequency Range *5 0.01 to 400Hz
Frequency Resolution *6 Digital command: ±0.01%,
Analog command: ±0.2% (25 ± 10℃)
Frequency Setting Resolution Digital: 0.1Hz, Analog: (max frequency)/1000
Voltage/Frequency Characteristics V/f control,V/f variable (constant torque, reduced torque)
Overload Capacity 150% for 60 sec.
Accel./Decel. Time 0.00 to 3000 sec. (linear, sigmoid), two-stage accel./decel.
Carrier Frequency Range 2.0 to 15.0 kHz
Protective Functions Over-current, Over-voltage, Under-voltage, Overload, Overheat, Ground fault at power-on, Input over-voltage, External trip, Memory error, CPU error, USP error, Driver error, Output phase loss protection
Input signal Frequency setting External signal*7
0 to 10 V DC or 4 to 20 mA, RS485 interface (Modbus RTU)
Operator keypad(Option)
Up and Down keys / Value settings or analog setting via potentiometer on operator keypad
FW/RV Run Operator Keypad(Option)
Run key / Stop key(change FW/RV by function command)
External signal
FW Run/Stop(NO contact), RV set by terminal assignment(NC/NO), 3-wire input available
Serial port
RS485 interface (Modbus RTU)
Intelligent Input 5 terminals
Analog Input 1 terminal( O/OI terminal:Voltage Input 10bit/ 0 to 10V,  Current input :10bit/ 0 to 20mA selectable with switch)
Output signal Intelligent output terminal 1 terminal
Intelligent Relay Output 1c output 250V AC/ 30V DC 2.5A relay
(AL0, AL1, AL2 terminals)
Moniter output terminal 1 terminal
Communication RS-422 RJ45 connector (common to RS485: selectable with switch)
For External Keypad, for ProDriveNext 
RS-485 RJ45connector (common to RS422, selectable with switch) Modbus-RTU
Other Function AVR (Automatic Voltage Regulation), V/f characteristic selection, frequency upper/lower limit, 8 stage multispeed, Start Frequency Adjustment, Jogging, Carrier Frequency Adjustment, PID control, frequency jump, external frequency input bias start/end, S-curve and linear Accel/Decel, DC braking, Electronic Thermal characteristics and level adjustment, retry function, Torque Boost, trip history, Software Lock Mode, Frequency, Scaling Conversion Factor setting, USP function, 2nd motor control, UP/DOWN, OC suppression etc
Environment, etc Operating Temperatu 10 to 50℃ (derating is neeeded for 40℃ and over)
Strage Temperature 20 to 65℃ (during short period for transportation)
Humidity 20 to 90% RH
Vibration 5.9mm/s2 (0.6G) 10 to 55Hz
Location Altitude 1,000 m or less, indoors
(no corrosive gasses or dust)
Color Black
Standards UL, CE, c-UL, c-tick
Option Remote operator with copy function (WOP), Remote operator (OPE-SRmini, OPE-SR), Operator (NES1-OP), input/output reactors, DC reactors, radio noise filters, LCR filter, communication cables (ICS-1, 3)

Note

*1
The applicable motor refers to Hitachi standard 3-phase motor (4-pole). When using other motors, care must be taken to prevent the rated motor current (50/60 Hz) from exceeding the rated output current of the inverter.
*2
The output voltage decreases as the main supply voltage decreases (except when using the AVR function). In any case, the output voltage cannot exceed the input power supply voltage.
*3
The braking torque via capacitive feedback is the average deceleration torque at the shortest deceleration (stopping from 50/60 Hz as indicated). It is not continuous regenerative braking torque. The average decel torque varies with motor loss. This value decreases when operating beyond 50 Hz.
*4
The protection method conforms to JIS C 0920(IEC60529).
*5
To operate the motor beyond 50/60 Hz, consult the motor manufacturer for the maximum allowable rotation speed.
*6
The output frequency may exceed the maximum frequency setting (A004 or A204) for automatic stabilization control.
*7
DC 4 to 20 mA Input, need parameter setting by Keypad etc.
Analog input voltage or current can be switched by switch as individually and not use them in the same time.

Product Inquiry