| Model X200- | European Version | 002SFEF2 | 004SFEF2 | 005SFEF2 | 007SFEF2 | |
|---|---|---|---|---|---|---|
| US Version | 002NFU2 | 004NFU2 | — | 007NFU2 | ||
| Output Ratings | Applicable motor size, 4-pole kW(HP) *1 | 0.2(1/4) | 0.4(1/2) | 0.55(3/4) | 0.75(1) | |
| Rated capacity | 230V | 0.5 | 1.0 | 1.1 | 1.5 | |
| 240V | 0.5 | 1.0 | 1.2 | 1.6 | ||
| Rated output current (A) *2 | 1.4 | 2.6 | 3.0 | 4.0 | ||
| Overloadcapacity (output current) | 150% for 60 sec. | |||||
| Rated output voltage (V) | 3-phase (3-wire) 200 to 240V (corresponding to input voltage) | |||||
| Input Rating | Rated input voltage (V) | SFEF: 1-phase 200 to 240V+10%, -15%, 50/60Hz±5% NFU: 1-/3-phase 200 to 240V+10%, -15%, 50/60Hz±5% LFU: 3-phase 200 to 240V+10%, -15%, 50/60Hz±5% |
||||
| Enclosure *4 | IP20 | |||||
| Cooling method | Self-cooling | |||||
| Integrated EMC filter | -SFEF | EN61800-3 category C1 filter | ||||
| -NFU/LFU | — | |||||
| Weight (kg) | -SFEF | 0.8 | 1.0 | 1.5 | 1.5 | |
| -NFU/LFU | 0.8 | 0.9 | — | 1.5 | ||
| Model X200- | European Version | 011SFEF2 | 015SFEF2 | 022SFEF2 | — | — | — | |
|---|---|---|---|---|---|---|---|---|
| US Version | — | 015NFU2 | 022NFU2 | 037LFU2 | 055LFU2 | 075LFU2 | ||
| Output Ratings | Applicable motor size, 4-pole kW(HP) *1 | 1.1(1.5) | 1.5 (2) | 2.2(3) | 3.7(5) | 5.5(7.5) | 7.5(10) | |
| Rated capacity | 230V | 1.9 | 2.8 | 3.9 | 6.3 | 9.6 | 12.7 | |
| 240V | 2.0 | 2.9 | 4.1 | 6.6 | 9.9 | 13.3 | ||
| Rated output current (A) *2 | 5.0 | 7.1 | 10.0 | 15.9 | 24.0 | 32.0 | ||
| Overloadcapacity (output current) | 150% for 60 sec. | |||||||
| Rated output voltage (V) | 3-phase (3-wire) 200 to 240V (corresponding to input voltage) | |||||||
| Input Rating | Rated input voltage (V) | SFEF: 1-phase 200 to 240V+10%, -15%, 50/60Hz±5% NFU: 1-/3-phase 200 to 240V+10%, -15%, 50/60Hz±5% LFU: 3-phase 200 to 240V+10%, -15%, 50/60Hz±5% |
||||||
| Enclosure *4 | IP20 | |||||||
| Cooling method | Force ventilation | |||||||
| Integrated EMC filter | -SFEF | EN61800-3 category C1 filter | ||||||
| -NFU/LFU | — | |||||||
| Weight (kg) | -SFEF | 2.4 | 2.4 | 2.5 | — | — | — | |
| -NFU/LFU | — | 2.3 | 2.4 | 2.3 | 4.2 | 4.2 | ||
| Model X200- | European Version | 004HFEF2 | 007HFEF2 | 015HFEF2 | 022HFEF2 | 030HFEF2 | 040HFEF2 | 055HFEF2 | 075HFEF2 | |
|---|---|---|---|---|---|---|---|---|---|---|
| US Version | 004HFU2 | 007HFU2 | 015HFU2 | 022HFU2 | — | 040HFU2 | 055HFU2 | 075HFU2 | ||
| Output Ratings | Applicable motor size, 4-pole kW(HP) *1 | 0.4(1/2) | 0.75(1) | 1.5 (2) | 2.2(3) | 3(4) | 4(5) | 5.5(7.5) | 7.5(10) | |
| Rated capacity | 400V | 1.0 | 1.7 | 2.6 | 3.8 | 5.4 | 5.9 | 9.0 | 11.1 | |
| 480V | 1.2 | 2.0 | 3.1 | 4.5 | 6.4 | 7.1 | 10.8 | 13.3 | ||
| Rated output current (A) *2 | 1.5 | 2.5 | 3.8 | 5.5 | 7.8 | 8.6 | 13.0 | 16.0 | ||
| Overload capacity (output current) | 150% for 60 sec. | |||||||||
| Rated output voltage (V) | 3-phase (3-wire) 380 to 480V (corresponding to input voltage) | |||||||||
| Input Rating | Rated input voltage (V) | 3-phase 380 to 480V +10%, -15%, 50/60Hz±5% | ||||||||
| Enclosure *4 | IP20 | |||||||||
| Cooling method | Self-cooling | Force ventilation | ||||||||
| Integrated EMC filter | -HFEF | EN61800-3 category C2 filter | ||||||||
| -HFU | — | |||||||||
| Weight (kg) | -HFEF | 1.5 | 2.3 | 2.4 | 2.4 | 2.4 | 2.4 | 4.2 | 4.2 | |
| -HFU | 1.4 | 2.2 | 2.3 | 2.3 | — | 2.3 | 4.2 | 4.2 | ||
| Control | Control method | Line-to-line sine wave pulse-width modulation (PWM) control | |
|---|---|---|---|
| Output frequency range *5 | 0.5 to 400Hz | ||
| Frequency accuracy *6 | Digital command :±0.01%, Analog command±0.4% (25 ±10°C) | ||
| Frequency setting resolution | Digital: 0.1Hz, Analog: (max frequency)/1000 | ||
| Voltage/Frequency Characteristic | V/f control, V/f variable (constant torque, reduced torque) | ||
| Acceleration/deceleration time | 0.01 to 3000 sec. (linear, sigmoid), two-stage accel./decel. | ||
| Starting torque *7 | 100%/6Hz | ||
| Carrier frequency range | 2.0 to 12kHz | ||
| Protective functions | Over-current, over-voltage, under-voltage, overload, overheat, ground fault at power-on, input over-voltage, external trip, EEPROM error, CPU error, USP error, Termister error, Driver error, Emergency stop. | ||
| Input terminal | Specification | 10kohm input impedance, sink/source logic selectable | |
| Functions | FW(Forward), RV(Reverse), CF1-CF4(Multispeed command), JG(Jogging), DB(External DC braking), SET(Second motor constants setting), 2CH(Second accel./decel.), FRS(Free-run stop), EXT(External trip), USP(Unattended start protection), SFT(Software lock), T(Analog input selection), RS(Reset), PTC(Thermistor input) *8, STA(3-wire start), STP(3-wire stop), F/R(3-wire fwd./rev.), PID(PID On/Off), PIDC(PID reset), UP/DWN(Remote-controlled accel./decel.) , UDC(Remote-controlled data clearing), OPE(Operator control), ADD(ADD frequency enable), FTM(force terminal mode), RDY(quick start enable), S-ST(Special-Set 2nd Motor Data), EMR(Emergency stop), NO(Not selected) | ||
| Output signal | Intelligent output terminal | Specification | 27V DC 50mA max open collector output, 1 terminals 1c output 250V AC/30V DC 2.5A relay (AL0, AL1, AL2 terminals) |
| Function | RUN(run signal), FA1(Frequency arrival type 1 - constant speed), FA2(Frequency arrival type 2 - over-frequency), OL(overload advance notice signal), OD(Output deviation for PID control), AL(alarm signal), DC(Wire brake detect on analog input), FBV(PID Second Stage Output), NDC(ModBus Network Detection Signal), LOG(Logic Output Function), ODC(Option Card Detection Signal), LOC(Low load) |
||
| Analog output terminal | Specification | 0 to 10V DC | |
| Function | Analog Frequency monitor, analog current monitor | ||
| Operator | Display | Specification | 4-digits 7 segment LEDs |
| Function | Parameter setting, output frequency, output current, scaled value of output frequency, trip history, I/O terminal condition, output voltage. Rotation direction, PID Feedback, RON time, Power-on time. |
||
| Status LED Interface | Power, Alarm, Run, Prg, Hz and A Potentiometer, RUN, STOP/RESET, UP, DOWN, FUN and STR keys |
||
| Operation | Frequency setting | Operator keypad | Up and Down keys / Value settings or analog setting via potentiometer on operator keypad |
| External signal | 0 to 10 V DC, 4 to 20 mA | ||
| Serial port | RS485 interface (Modbus RTU) | ||
| FW/RV Run | Operator Keypad | Run key / Stop key (change FW/RV by function command) | |
| External signal | FW Run/Stop (NO contact), RV set by terminal assignment (NC/NO), 3-wire input available | ||
| Serial port | RS485 interface (Modbus RTU) | ||
| Environment | Operating temperature | −10 to 50°C(carrier derating required for aambient temperature higher than 40°C), no freezing | |
| Storage temperature | -20 to 65°C | ||
| Humidity | 20 to 90% RH | ||
| Vibration | 5.9mm/s2 (0.6G) 10 to 55Hz | ||
| Location | Altitude 1,000 m or less, indoors (no corrosive gasses or dust) | ||
| Other functions | AVR (Automatic Voltage Regulation), V/f characteristic selection, accel./decel. curve selection, frequency upper/lower limit, 16 stage multispeed, PID control, frequency jump, external frequency input bias start/end, jogging, cooling fan On/Off, trip history etc. | ||
| Coating color | Blue | ||
| Options | Remote operator with copy function (SRW-0EX), input/output reactors, DC reactors, radio noise filters, braking resistors, braking units, LCR filter, communication cables (ICS-1, 3) |
||
Product Inquiry