Jump to the main text

Hitachi Industrial Equipment Systems Co.,Ltd.

Hitachi

The X200 series can be easily operated with the digital operator provided as standard.
The digital operator can also be detached and used for remote-control. An operator with copy function is also available as an option.

Operation and Programming

1. Setting the maximum output frequency

Setting the maximum output frequency

2. Running the motor(by potentiometer)

Running the motor(by potentiometer)

3. Monitoring output current value

Monitoring output current value

Hardware switches

Hardware switches

Switch symbol Switch NameSwitch Name Description
SW7RS-485
communication/key pad
selection switch
Select communication connector distination. *1
485 RS-485 communicaiton via Modbus protocol
OPE [default] Keypad (option)
SW8 Emergency stop ON/OFF Select frequency and run command input source.
The SW8 is for the emergency signal input. If you turn this DIP switch ON, the inverter is ready to receive emergency signal from the dedicated terminal #3. Inverter shuts off the output by means of pure hardware when a signal is given to the terminal. Each signals related to this emergency input must be in accordance with the norm. Additionally, the logic input terminal assign will be changed automatically if the SW8 is made ON.
*1
The standard keypad OPE (OPE-SRmini) can be used either the switch is set to 485 or OPE.
*2
Input terminal selection (EMR) cannot be chosen from an operaator. If the slide switch SW8 is turned ON, it divides automatically and is attached.

Product Inquiry