High starting torque of 200% or greater at 0.5 Hz. *1
| Applicable motor | Starting torque |
|---|---|
| 11 to 75kW | 0.5Hz/150% |
| 90 to 160kW | 0.5Hz/120% |
Higher internal calculation speed* improve current control performance Over-current suppress and Over-voltage suppress function avoid inverter trip during acceleration and deceleration period.


Simple sequence operation is realized by downloading to an inverter the program created by programming soft EzSQ.
It is also possible to automatic speed control according to a load situation like a swift lift function for crane or a conveyor, and to operate.
Since an external circuit can be simplified, a control board is made small and a cost cut can be aimed at.
Cost and space reduction compared with external EMC Filter (All models).
Reduces electromagnetic noise.
EN61800-3 2nd-Environment
Cost and Space reduction compared with external Braking Controller
Field replacement of cooling fan(s) and DC bus capacitor can be accomplished in a fraction of the time.
Cooling fanON/OFF control provides longer life.
Using Logic terminal move to L700/SJ700B without wiring change.
Read L300P Parameter by WOP remote operator and write them in to L700/SJ700B.

| Series | Input terminals | Output terminals |
|---|---|---|
| SJ700 L700 SJ700B SJ300 |
9 terminals (Intelligent 8 terminals,FW) |
5 terminals (Open collector outputs) |
| L300P | 6 terminals (Intelligent 5 terminals,FW) |
2 terminals (Relay outputs) |
Design lifetime 10 Years or more Dc bus capacitor & Cooling Fan.
Cooling Fan ON/OFF control lead more longer life time
Avoid trouble before the malfunction by lifetime Warning signal.
The monitor of the temperature rise of a Dc bus capacitor, cooling fan degradation degree, a cooling fin, and a motor can be carried out.
Replace the components before the malfunction.
A display of only the parameter changed from the default is possible.
Indication User setting 12 Parameters as U001-U012.

Indication Basic Parameter for common used Parameters.
The port corresponding to RS-485 Modbus-RTU is equipped as standard.
SJ700 can communicate with DeviceNet PROFIBUS-DP LonWorks with communication options.
Input voltage 240V for 200V class and 480V for 400V class as standard.
Hitachi original PWM control suppressing Motor terminal voltage less than 2 times of INV DC voltage E.Lower than Hitachi motor Max. insulation voltage (1,250V) (during regenerating operation increase the DC bus voltage may over motor max. insulation voltage)

EU RoHS compliant by restricting to use hazardous substances.
(except solder in power module)
Varnish coating of internal PC board & plating of main circuit copper bus bar as standard.
NOTE
If you have any question about choosing inverter, please contact us.
Product Inquiry