Hitachi

Model
item, unit
Without Dryer Model Dryer built-in Model Without Dryer Model Without Dryer Model
DSP-55VWT5
DSP-55VWT6
DSP-55VWTR5
DSP-55VWTR6
DSP-75VW5L(M)
DSP-75VW6L(M)
DSP-100VW5M
DSP-100VW6M
Discharge air pressure MPa 0.69 0.88 0.69 0.88 0.69 0.88 0.69 0.88
Capacity m3/min 8.7 6.8 8.7 6.8 12.0 10.0 17.2 14.5
Intake air pressure temperature °C Atmospheric Pressure/0-40 Atmospheric Pressure/5-40 Atmospheric Pressure/0-40
Driving method V-belt + Gear-driven Direct coupling + Gear-driven
Capacity control system Inverter control + purge control
Discharge air temperature °C Cooling water temperature + 13 or less
Discharge pipe diameter L 1 1/2 2 (flange)
Amount of cooling water L/min 80 120 160
Cooling water temperature °C 32 or Less
Cooling water pipe diameter B 1 1/4 1 1/2
Motor Output kW 55 75 100
Motor type 4-pole TEFC Motor 2-pole TEFC Motor
Starting Method Inverter
Cooling fan motor output kW 0.2 0.2 0.4 0.2 0.4
Oil pump Output kW 0.4 0.75
Lubricating oil capacity L 18(Not filled in) 20(Not filled in) 25(Not filled in)
Dryer Dew point of outlet air Celsius Lower than 10
(Ambient temp.30 celsius)
Chiller output kW 2.2
Refrigerant HFC-R407C
Fan motor output W 20 × 4
Weight kg 1,580 1,780 2,150 2,520
Dimensions (W × D × H) mm 1,780 × 1,150 × 1,530 2,230 × 1,150 × 1,530 2,650 × 1,100 × 1,530 2,800 × 1,100 × 1,530
Noise level (1.5m from front side) dB[A] 64 64 64 64 65 67 67 69

Note

*1
Capacity is the converted value at its inlet condition.
2
The appearance and specifications are subject to change without prior notice.
3
Do not use any of the compressors with a respiratory device that directly sucks compressed air.
4
Motor output is the nominal output.
5
The discharge air pressure is the gauge pressure.
6
Sound level is the value in an anechoic room from 1.5m at full load.
7
Install the compressor indoors in an atmosphere free of explosive and corrosive gases and at a place not exposed to excessive moisture or dust.