Hitachi

Model
item, unit
Without Dryer Model Dryer built-in Model
DSP-22VA5I
DSP-22VA6I
DSP-37VA5I
DSP-37VA6I
DSP-55VA5I
DSP-55VA6I
DSP-22VAR5I
DSP-22VAR6I
DSP-37VAR5I
DSP-37VAR6I
DSP-55VAR5I
DSP-55VAR6I
Rated specs Discharge air pressure MPa 0.69
Capacity m3/min 3.4 4.2 6.4 3.4 4.2 6.4
In PQ wide mode Discharge air pressure MPa 0.39 0.49 0.39 0.49
Capacity m3/min 4.3 5.0 8.2 4.0 5.0 7.6
Operating range of PQ wide mode MPa 0.39 - 0.69 0.49 - 0.69 0.39 - 0.69 0.49 - 0.69
Intake air press./temp. °C Atmospheric pressure /0-40 Atmospheric Pressure/5-40
Driving method V-belt + Gear-driven
Capacity control system Inverter control + purge control
Discharge air temperature °C Atmospheric temperature + 15 or less
Discharge pipe diameter B 1 1 1/2 1 1 1/2
Motor Output kW 22 37 55 22 37 55
Motor type 4-pole TEFC Motor
Starting Method Inverter
Cooling fan motor output kW 0.75 0.75 0.9 0.75 0.75 0.9
Coolant pump motor output kW(50/60Hz) 0.2/0.3
Lubricating oil capacity L 12(Not filled in) 18(Not filled in) 12(Not filled in) 18(Not filled in)
Dryer Dew point of outlet air Celsius 10 or Less (Ambient temp.30 celsius)
Chiller output kW 1.1
Refrigerant HFC-R407C
Fan motor output W 25 120
Weight kg 850 1,080 1,180 880 1,230 1,330
Dimensions (W × D × H) mm 1,650 × 970 × 1,400 1,780 × 980 × 1,500 1,650 × 970 × 1,400 2,180 × 980 × 1,500
Noise level (1.5m from front side) dB[A] 63 66 68 63 66 68

Note

*1
Capacity is the converted value at its inlet condition.
2
The appearance and specifications are subject to change without prior notice.
3
Do not use any of the compressors with a respiratory device that directly sucks compressed air.
4
Motor output is the nominal output.
5
The discharge air pressure is the gauge pressure.
6
Sound level is the value in an anechoic room from 1.5m at full load.
7
Install the compressor indoors in an atmosphere free of explosive and corrosive gases and at a place not exposed to excessive moisture or dust.
8
When operating at the lowest pressure within PQ WIDEMODE range, the dew point of outlet air increases approx. 3°C