Hitachi

Without Dryer Model

Model
item, unit
DSP-15A5 II
DSP-15A6 II
DSP-22A5 II
DSP-22A6 II
DSP-37A5 II
DSP-37A6 II
DSP-45A5 II
DSP-45A6 II
DSP-55A5 II
DSP-55A6 II
Discharge air pressure MPa 0.69 0.39 0.69 0.39 0.69 0.39 0.69 0.39 0.69 0.39
Capacity m3 /min 2.0 2.5 3.4 4.0 4.2 5.9 5.0 6.8 6.4 8.0
Motor output kW 15 22 37 45 55
Intake air pressure temperature °C Atmospheric Pressure/0 - 40
Discharge air temperature °C Atmospheric Temperature+15or Less
Discharge pipe diameter B 1 11 /2
Starting method Direct start Star-delta(3contactors)
Driving method V-belt + Gear-driven
Cooling fan motor output kW 0.75 0.9
Coolant pump motor output kW(50/60Hz) 0.2 / 0.3
Lubricating oil capacity L 12(Not filled in) 18(Not filled in)
Weight kg 750 800 1,020 1,240 1,240
Dimensions (W × D × H) mm 1,400 × 970 × 1,400 1,780 × 980 × 1,500
Noise level (1.5m from front side) dB(A) 62 63 63 64 66 68 67 69 68 70

Dryer built-in Model

Model
item, unit
DSP-15AR5 II
DSP-15AR6 II
DSP-22AR5 II
DSP-22AR6 II
DSP-37AR5 II
DSP-37AR6 II
DSP-45AR5 II
DSP -45AR6 II
DSP-55AR5 II
DSP-55AR6 II
Discharge air pressure MPa 0.69
Capacity m3/min 2.0 3.4 4.2 5.0 6.4
Motor output kW 15 22 37 45 55
Intake air pressure temperature °C Atmospheric Pressure/5 - 40
Discharge air temperature °C Atmospheric Temperature+15or Less
Discharge pipe diameter B 1 11/2
Starting method Direct start Star-delta(3contactors)
Driving method V-belt + Gear-driven
Cooling fan motor output kW 0.75 0.9
Coolant pump motor output kW(50/60Hz) 0.2 / 0.3
Lubricating oil capacity L 12(Not filled in) 18(Not filled in)
Dryer Dew point of outlet air Celsius 10 or less (Ambient temp.30 celsius)
Chiller output kW 0.5 1.1
Refrigerant HFC-R407C
Fan motor output W 25 25 × 2 120
Weight kg 780 830 1,170 1,390 1,390
Dimensions (W × D × H) mm 1,400 × 970 × 1,400 2,180 × 980 × 1,500
Noise level (1.5m from front side) dB(A) 62 63 66 67 68

Note

*1
Capacity is the converted value at its inlet condition.
2
The appearance and specifications are subject to change without prior notice.
3
Do not use any of the compressors with a respiratory device that directly sucks compressed air.
4
Motor output is the nominal output.
5
The discharge air pressure is the gauge pressure.
6
Sound level is the value in an anechoic room from 1.5m at full load.
7