Jump to the main text

Hitachi Industrial Equipment Systems Co.,Ltd.

Hitachi

High Energy Efficiency

Improved compressor efficiency

The newly-developed high-efficiency air end has increased the air discharge rate by 2 - 21% over an conventional model.

Water-cooled two-stage model 75kW (0.69MPa)

unit:m3/min

Water-cooled two-stage model 75kW (0.69MPa) 11%up

Two-stage model 55kW (0.69MPa)

unit:m3/min

Two-stage model 55kW (0.69MPa)

Single-stage model 22kW (0.69MPa)

unit:m3/min

Single-stage model 22kW (0.69MPa)

Power-saving operation (patent pending)

This new function automatically controls the unload pressure according to the air consumption, thereby maintaining optimum air pressure.Thus, it allows for energy-saving operation of the compressor.
As an example, New DSP 75kW two-stage model, can save approx.9% of power consumption at 90 % load.(Air receiver volume 2.5m3)

Power-saving operation (patent pending)

Reduction of Noise

The structure of the drive unit's vibration-proof support has been improved to reduce the level of noise propagated through the solid frame. The suction and exhaust noise has also been reduced.
As a result, the level of noise has been reduced by 5-6dB(A) in water-cooled Two-stage models and by 2-6dB(A) in air-cooled two-stage models.

water-cooled model

Air-cooled model

improved Reliability and Mainteinability

improved Reliability and Mainteinability

Totally-enclosed, fan-cooled (TEFC) motor provided as standard

In order to improve the motor reliability, TEFC has been provided as standard (except for compressors of 3,000 / 3,300V specification).

Improved maintainability

The maintainability including filter replacement and cooler cleaning has been improved. (The photograph is a 55kW air-cooled model.)

Prolonged Parts Replacement and Overhaul Intervals

Prolonged Parts Replacement and Overhaul Intervals

The overhaul interval has been prolonged to 6 years (4 years for conventional models). Also, the replacement interval for the belt (for single-stage models) and other parts have been prolonged.

Advanced Functions

Large LCD monitor offers a better user interface

Large LCD monitor offers a better user interface

The large LCD monitor allows the operator to check the compressors operating condition and various settings at a glance. In addition, the monitor is provided with such new functions as storage of operation data, alternate compressor operation, and communications, offering remarkably improved user interface.

Monitor Storage operation data Maintenance timing display

Monitor

Displays the current operating condition of the compressor on 3 screens (compressor operating hours, temperature, current, etc.) at a glance. The monitor screens can be switched at a touch of a button.

Storage operation data

Stores operation data of the compressor at a preset time once in a day. The data stored can be used for compressor operation control, etc.

Maintenance timing display

When the scheduled maintenance time comes, it is automatically displayed on the LCD monitor. During automatic operation, an advance notice of the restart time and automatic stop is also displayed.
Two-step alarm display Detailed failure history display Load data recording
If the temperature or pressure becomes abnormal, an alarm is displayed before the compressor shut down. A history of up to 6 failures and the operation data right before the failure are memorized and displayed for quick trouble shooting. Average pressure, average load ratio, etc. during daily operation can be displayed.
Setup and check screen
The setting of compressor functions can be done on the instrument panel.

Scheduled operation

This function allows for automatic operation of the compressor by setting a start time and a stop time. Up to five start/stop times can be set on a daily basis. Thus, it is possible to set operating hours of the compressor according to the work schedule, such as lunch break and coffee break.

Product Inquiry