  7.5B 11B 15B 22B 37B 55B 75B 100B 125B 160B 200B 240B
Model HMF-7.5BX HMF-11B HMF-15B HMF-22B HMF-37B HMF-55B HMF-75B HMF-100B HMF-125B HMF-160B HMF-200B HMF-240B
air
condition
Air processing capacity
(at atmospheric pressure)
m3/min 1.2 1.8 2.4 3.9 6.6 10.6 13.8 20 27.6 32.0 40.0 50.0
Inlet air temperature °C 30
Inlet air pressure MPa 0.69
Use
conditions
Fluid used - Compressed air
Max. operating pressure MPa 0.97
Inlet air temperature range °C 5 - 60
Ambient temperature range °C 2 - 60
Outlet oil content wtppm 0.01 Note*2
Pressure loss Initial stage MPa 0.01
Replacement stage MPa 0.07
Dimensions
(diameter × length)
mm 92
×
237
115
×
368
115
×
536
160
×
582
170
×
664
170
×
772
173
×
865
173
×
1,022
590
×
1,512
590
×
1,512
590
×
1,512
640
×
1,735
Discharge drain port diameter - PT1/4
Weight kg 1 1.5 2 3 3.3 3.7 4.3 6 57 61 61 73
Connecting pipe diameter B Rc3/4 Rc3/4 Rc3/4 Rc1 Rc1-1/2 Rc1-1/2 Rc2 Rc2 2-1/2 Flange 3 Flange 3 Flange 4 Flange
*
Install an air dryer in the pre-stage of these filters.

Note

*2
corresponds to the 1st grade of "compressed air grades" in ISO8573-1. The inlet oil content is 3wtppm.