Hitachi

  7.5B 11B 15B 22B 37B 55B 75B 100B 125B 160B 200B 240B
Model HAF-7.5BX HAF-11B HAF-15B HAF-22B HAF-37B HAF-55B HAF-75B HAF-100B HAF-125B HAF-160B HAF-200B HAF-240B
air
condition
Air processing capacity
(at atmospheric pressure)
m3/min 1.2 1.8 2.4 3.9 6.6 10.6 13.8 20 27.6 32.0 40.0 50.0
Inlet air temperature °C 30
Inlet air pressure MPa 0.69
Use
conditions
Fluid used - Compressed air
Max. operating pressure MPa 0.97
Inlet air temperature range °C 5 - 60
Ambient temperature range °C 2 - 60
Filtration µm 1 Note*1
Pressure
drop
Initial stage MPa Less than 0.005
Replacement stage MPa 0.07
Dimensions
(diameter × length)
mm 92
×
237
115
×
287
115
×
455
160
×
509
170
×
591
170
×
699
173
×
792
173
×
949
590
×
1,512
590
×
1,512
590
×
1,512
640
×
1,735
Weight kg 1 1.5 2 3 3.3 3.7 4.3 6 57 61 61 73
Connecting pipe diameter B Rc3/4 Rc3/4 Rc3/4 Rc1 Rc1-1/2 Rc1-1/2 Rc2 Rc2 2-1/2 Flange 3 Flange 3 Flange 4 Flange
*
Install an air dryer in the pre-stage of these filters.

Note

*1
corresponds to the 2nd grade of "compressed air grades" in ISO8573-1. The inlet oil content is 3wtppm.