Large Capacity Models (HDR-120AX/WX to HDR-380AX/WX)

    HDR-120WX HDR-150WX HDR-190WX HDR-240WX HDR-300WX HDR-380WX HDR-120AX HDR-150AX HDR-190AX HDR-240AX HDR-300AX HDR-380AX
Frequency Hz 50 60 50 60 50 60 50 60 50 60 50 60 50 60 50 60 50 60 50 60 50 60 50 60
Capacity *1 m3/min 21 25 27 31 35 41 42 49 51 60 64 75 20 23 25 30 32 38 38 45 47 55 59 69
Maximum Inlet Air Pressure Mpa 0.97 0.93 0.97 0.93
Maximum Inlet Air Temperature °C 60
Ambient Operating Temperature °C 20 to 40
Outlet Air Dew Point °C 10 under pressure
Refrigerant Compressor Motor Nominal Output kW 2.2 3.0 3.75 3.75 2.2×2 3.0×2 2.2 3.0 3.75 3.75 2.2×2 3.0×2
Condenser Cooling Method   Water-Cooled Air-Cooled by Cooling Fan
Refrigerant Control Method   Capilary Tube
Refrigerant   R-407C
External Coating   Ivory
Discharge Air Pipe Connection inch 2 1/2
Flange
3
Flange
3
Flange
4
Flange
5
Flange
5
Flange
2 1/2
Flange
3
Flange
3
Flange
4
Flange
5
Flange
5
Flange
External Dimensions(W×D×H) mm 672
×
1260
×
1276
950
×
1290
×
1332
950
×
1290
×
1332
1969
×
905
×
1583
2020
×
1100
×
1650
2020
×
1100
×
1650
672
×
1260
×
1276
950
×
1290
×
1332
950
×
1290
×
1332
1969
×
905
×
1583
2020
×
1100
×
1650
2020
×
1100
×
1650
Approximate Weight kg 238 346 344 534 792 872 258 372 370 557 792 872
Standard Accessory   Condensate Drain Value and Automatic Condensate Drain Trap

Note

*